{"product_id":"dragino-dr-ec200-rs485-modbus-conductivity-and-salinity-probe","title":"Dragino DR-EC200 | RS485 Modbus Conductivity and Salinity Probe","description":"\u003cdiv class=\"shopiot-detailed-description\" style=\"max-width: 800px; font-family: 'DM Sans', sans-serif; color: #2a2b2a; line-height: 1.6; font-size: 16px;\"\u003e\n\u003csection style=\"margin-bottom: 35px;\"\u003e\u003cp\u003eThe \u003cstrong\u003eDragino DR-EC200\u003c\/strong\u003e is a four-electrode conductivity probe for water that conducts a lot: seawater, aquaculture ponds, sewage and process water. It is made for integrators and water-quality teams who need readings that stay usable far above the range of standard EC probes.\u003c\/p\u003e\n\u003cp\u003eOne probe returns electrical conductivity, salinity and water temperature through a single RS485 Modbus-RTU connection. It runs on 7 to 30 VDC and draws less than 0.5 W.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-bottom: 18px; font-weight: bold; text-transform: uppercase;\"\u003eCore Capabilities\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\" aria-hidden=\"true\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpolyline points=\"22 12 18 12 15 21 9 3 6 12 2 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eFour-electrode measurement\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eReads 1 to 200,000 µS\/cm with 1 µS\/cm resolution and ±1% FS accuracy, so brackish and salt water stay in range.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\" aria-hidden=\"true\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M14 14.76V3.5a2.5 2.5 0 0 0-5 0v11.26a4.5 4.5 0 1 0 5 0z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eSalinity and temperature\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eSalinity from 0 to 70 PSU (0.1 PSU resolution) and water temperature from -5 to +80 °C (±0.5 °C) come from the same probe.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\" aria-hidden=\"true\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cline x1=\"4\" y1=\"21\" x2=\"4\" y2=\"14\"\u003e\u003c\/line\u003e\u003cline x1=\"4\" y1=\"10\" x2=\"4\" y2=\"3\"\u003e\u003c\/line\u003e\u003cline x1=\"12\" y1=\"21\" x2=\"12\" y2=\"12\"\u003e\u003c\/line\u003e\u003cline x1=\"12\" y1=\"8\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003cline x1=\"20\" y1=\"21\" x2=\"20\" y2=\"16\"\u003e\u003c\/line\u003e\u003cline x1=\"20\" y1=\"12\" x2=\"20\" y2=\"3\"\u003e\u003c\/line\u003e\u003cline x1=\"1\" y1=\"14\" x2=\"7\" y2=\"14\"\u003e\u003c\/line\u003e\u003cline x1=\"9\" y1=\"8\" x2=\"15\" y2=\"8\"\u003e\u003c\/line\u003e\u003cline x1=\"17\" y1=\"16\" x2=\"23\" y2=\"16\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eTemperature compensation\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eAutomatic compensation from -5 to +80 °C, referenced to 25 °C, with an adjustable coefficient (default 0.2).\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\" aria-hidden=\"true\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eRugged probe\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eIP68 (except the connector), 0.6 MPa maximum pressure and a 5 m cable for submerged or in-line use.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px; background-color: #fafafa; border-left: 4px solid #7765E3; padding: 20px; border-radius: 2px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-top: 0; margin-bottom: 12px; font-weight: bold; text-transform: uppercase;\"\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cdiv style=\"margin: 0; font-size: 15px;\"\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eAquaculture:\u003c\/strong\u003e Track conductivity and salinity in ponds and tanks.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eSeawater and brackish water:\u003c\/strong\u003e Monitor high-conductivity water up to 200,000 µS\/cm.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eSewage treatment:\u003c\/strong\u003e Continuous conductivity readings in treatment processes.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eEnvironmental protection:\u003c\/strong\u003e Cross-section and surface water monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003ePharmaceutical and food:\u003c\/strong\u003e Conductivity checks in process water.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eTap water:\u003c\/strong\u003e Ongoing conductivity monitoring of supply water.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-bottom: 10px; font-weight: bold; text-transform: uppercase;\"\u003eTechnical Integration\u003c\/h2\u003e\n\u003cdiv style=\"font-size: 14px; color: #555;\"\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eConnectivity:\u003c\/strong\u003e RS485 with standard Modbus-RTU, 9600 baud, 8 data bits, no parity, 1 stop bit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eData:\u003c\/strong\u003e One Modbus read returns conductivity, temperature and salinity.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e One- and two-point calibration over Modbus with 1413 µS\/cm and 111310 µS\/cm standards.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 7 to 30 VDC supply, under 0.5 W.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Side wall, top flange, pipe bend, flow-through or submerged installation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eSetup help:\u003c\/strong\u003e The ShopIoT team can help with wiring, Modbus registers and choosing a mounting method.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-bottom: 14px; font-weight: bold; text-transform: uppercase;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eWhat conductivity range does the DR-EC200 measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003e1 to 200,000 µS\/cm with 1 µS\/cm resolution and ±1% FS accuracy.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eDoes it measure salinity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eYes. Salinity is reported from 0 to 70 PSU with 0.1 PSU resolution, together with conductivity and water temperature.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eHow does it connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eOver RS485 using Modbus-RTU at 9600 baud, through a 5 m cable.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eWhat power supply does it need?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003e7 to 30 VDC. Power consumption is below 0.5 W.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eCan it be used underwater?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eThe probe is IP68, except the connector, and is rated to 0.6 MPa. It can be installed submerged, in a flow-through cell or on a pipe.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eHow often should it be calibrated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eCalibrate before each use and about every 3 months for long-term use.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Dragino","offers":[{"title":"Default Title","offer_id":57786490290500,"sku":"DR-EC200","price":258.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0418\/3749\/4423\/files\/dragino-dr-ec200-conductivity-salinity-probe.webp?v=1795288648","url":"https:\/\/shopiot.eu\/products\/dragino-dr-ec200-rs485-modbus-conductivity-and-salinity-probe","provider":"shopioT","version":"1.0","type":"link"}