{"product_id":"eastron-dcm232-dual-channel-dc-energy-meter-with-rs485-modbus-rtu","title":"Eastron DCM232 | Dual-Channel DC Energy Meter with RS485 Modbus RTU","description":"\u003cdiv class=\"shopiot-detailed-description\" style=\"max-width: 800px; font-family: 'DM Sans', sans-serif; color: #2a2b2a; line-height: 1.6; font-size: 16px;\"\u003e\n\u003csection style=\"margin-bottom: 35px;\"\u003e\u003cp\u003eThe \u003cstrong\u003eEastron DCM232\u003c\/strong\u003e is a dual-channel DC energy meter for DC systems, and especially for EV chargers with two outlets. It is for charger builders, panel builders and energy managers who need to meter each outlet separately.\u003c\/p\u003e\n\u003cp\u003eEach channel measures voltage, current, power and energy, with import, export and total kWh. Readings go to your controller over RS485 Modbus RTU, and each channel has its own pulse output. The meter sits on a 35 mm DIN rail and is 72 mm wide.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-bottom: 18px; font-weight: bold; text-transform: uppercase;\"\u003eCore Capabilities\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\" aria-hidden=\"true\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003crect x=\"4\" y=\"4\" width=\"16\" height=\"16\" rx=\"2\" ry=\"2\"\u003e\u003c\/rect\u003e\u003crect x=\"9\" y=\"9\" width=\"6\" height=\"6\"\u003e\u003c\/rect\u003e\u003cline x1=\"9\" y1=\"1\" x2=\"9\" y2=\"4\"\u003e\u003c\/line\u003e\u003cline x1=\"15\" y1=\"1\" x2=\"15\" y2=\"4\"\u003e\u003c\/line\u003e\u003cline x1=\"9\" y1=\"20\" x2=\"9\" y2=\"23\"\u003e\u003c\/line\u003e\u003cline x1=\"15\" y1=\"20\" x2=\"15\" y2=\"23\"\u003e\u003c\/line\u003e\u003cline x1=\"20\" y1=\"9\" x2=\"23\" y2=\"9\"\u003e\u003c\/line\u003e\u003cline x1=\"20\" y1=\"14\" x2=\"23\" y2=\"14\"\u003e\u003c\/line\u003e\u003cline x1=\"1\" y1=\"9\" x2=\"4\" y2=\"9\"\u003e\u003c\/line\u003e\u003cline x1=\"1\" y1=\"14\" x2=\"4\" y2=\"14\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eTwo independent channels\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eChannel 1 and channel 2 each report voltage, current, power and kWh. Keypad shortcuts jump straight to either channel on the display.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\" aria-hidden=\"true\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpolygon points=\"13 2 3 14 12 14 11 22 21 10 12 10 13 2\"\u003e\u003c\/polygon\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eBi-directional energy\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eImport, export and total kWh are recorded per channel with Class 1 active energy accuracy to IEC 62053-41.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\" aria-hidden=\"true\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpolygon points=\"13 2 3 14 12 14 11 22 21 10 12 10 13 2\"\u003e\u003c\/polygon\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eShunt-based current input\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eConnects to an external 75 mV shunt (60 mV optional). Set the primary current from 1 to 1999 A to match the shunt.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\" aria-hidden=\"true\"\u003e\u003csvg width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M18 8A6 6 0 0 0 6 8c0 7-3 9-3 9h18s-3-2-3-9\"\u003e\u003c\/path\u003e\u003cpath d=\"M13.73 21a2 2 0 0 1-3.46 0\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eCharger line loss and alarm\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eOptional line loss compensation takes the charger cable resistance (0-999.9 mOhm) into account. An LED and a Modbus register flag over-current.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px; background-color: #fafafa; border-left: 4px solid #7765E3; padding: 20px; border-radius: 2px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-top: 0; margin-bottom: 12px; font-weight: bold; text-transform: uppercase;\"\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cdiv style=\"margin: 0; font-size: 15px;\"\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eDual-outlet DC EV chargers:\u003c\/strong\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eDC distribution panels:\u003c\/strong\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eEnergy monitoring and sub-metering:\u003c\/strong\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-bottom: 10px; font-weight: bold; text-transform: uppercase;\"\u003eTechnical Integration\u003c\/h2\u003e\n\u003cdiv style=\"font-size: 14px; color: #555;\"\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eModbus RTU:\u003c\/strong\u003e RS485 at 2400 to 38400 bps (9600 default), addresses 001 to 247, with a response time under 30 ms.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eAddress modes:\u003c\/strong\u003e Use one address with a register block per channel, or two addresses with one per channel.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003ePulse outputs:\u003c\/strong\u003e Two passive outputs, one per channel, to IEC 62053-31 Class A. Each can follow import, export or total kWh.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003ePower and mounting:\u003c\/strong\u003e Runs from a 9-40 V DC auxiliary supply and clips onto a 35 mm DIN rail inside a cabinet or switchboard.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eVariant note:\u003c\/strong\u003e This listing is the non-MID version. MID versions of the DCM232 series are separate items.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 8px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\" aria-hidden=\"true\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eSetup help:\u003c\/strong\u003e The ShopIoT team can help you choose a shunt and set up Modbus or pulse wiring. Get in touch before you order.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-bottom: 14px; font-weight: bold; text-transform: uppercase;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eWhat does the DCM232 measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eFor each of its two channels it measures voltage, current and power, and records import, export and total kWh.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eCan it meter two EV charger outlets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eYes. The two channels are independent, each with its own pulse output, and Modbus can use one address or one address per channel.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eWhich current shunt does it use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eIt takes an external 75 mV shunt, with 60 mV optional. Set the primary current on the meter (1 to 1999 A) to match the shunt you fit.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eCan I power it from AC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eNo. It needs a 9-40 V DC auxiliary supply and must not be connected to an AC network.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eWhat Modbus settings are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eBaud rates of 2400, 4800, 9600 (default), 19200 and 38400, parity none, odd or even, 1 or 2 stop bits and addresses 001 to 247.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px;\"\u003e\u003cstrong\u003eCan I install it outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px; color: #555;\"\u003eNo. The front panel is IP51 for indoor use, and the operating range is -25 C to +55 C. Mount it inside a cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin-bottom: 35px;\"\u003e\u003ch2 style=\"color: #7765e3; font-size: 16px; margin-bottom: 14px; font-weight: bold; text-transform: uppercase;\"\u003eCertifications\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 10px;\"\u003e\n\u003cdiv style=\"display: inline-flex; align-items: center; gap: 8px; padding: 10px 16px; border: 1px solid #e8e4ff; border-radius: 4px; background: #f9f8ff;\"\u003e\n\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#7765e3\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003cspan style=\"font-size: 13px; font-weight: 600; color: #2a2b2a;\"\u003eIEC 61010-1, measurement category CAT III, protective class II\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: inline-flex; align-items: center; gap: 8px; padding: 10px 16px; border: 1px solid #e8e4ff; border-radius: 4px; background: #f9f8ff;\"\u003e\n\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#7765e3\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003cspan style=\"font-size: 13px; font-weight: 600; color: #2a2b2a;\"\u003eEMC: IEC 61326-1:2013 and IEC 61326-2-3:2013\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: inline-flex; align-items: center; gap: 8px; padding: 10px 16px; border: 1px solid #e8e4ff; border-radius: 4px; background: #f9f8ff;\"\u003e\n\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#7765e3\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003cspan style=\"font-size: 13px; font-weight: 600; color: #2a2b2a;\"\u003eUL 61010-1 and UL 61010-2-030\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: inline-flex; align-items: center; gap: 8px; padding: 10px 16px; border: 1px solid #e8e4ff; border-radius: 4px; background: #f9f8ff;\"\u003e\n\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#7765e3\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\"\u003e\u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003cspan style=\"font-size: 13px; font-weight: 600; color: #2a2b2a;\"\u003eCSA C22.2 No. 61010-1 and 61010-2-030\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Eastron","offers":[{"title":"Default Title","offer_id":57831983022404,"sku":"DCM232-2-3-1-1 (NON-MID)","price":150.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0418\/3749\/4423\/files\/eastron-dcm232-dual-channel-dc-energy-meter.webp?v=1795710842","url":"https:\/\/shopiot.eu\/products\/eastron-dcm232-dual-channel-dc-energy-meter-with-rs485-modbus-rtu","provider":"shopioT","version":"1.0","type":"link"}