{"product_id":"seeed-studio-s-dts210-01-industrial-turbidity-sensor-rs485","title":"Seeed Studio S-DTS210-01 | Industrial Turbidity \u0026 Temperature Sensor (RS485 Modbus RTU)","description":"\u003cdiv style=\"max-width: 800px; font-family: 'DM Sans', sans-serif; color: #2a2b2a; line-height: 1.6; font-size: 16px;\" class=\"shopiot-detailed-description\"\u003e\n\u003csection style=\"margin-bottom: 35px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eSeeed Studio S-DTS210-01\u003c\/strong\u003e is a professional industrial-grade sensor designed to measure liquid turbidity and temperature with exceptional stability. Utilizing the \u003cstrong\u003e90° scattered light principle\u003c\/strong\u003e and an infrared LED light source, this sensor minimizes interference from ambient light and liquid color, providing highly accurate NTU readings. Housed in a rugged, corrosion-resistant body with an \u003cstrong\u003eIP68 protection rating\u003c\/strong\u003e, it is engineered for permanent immersion in wastewater treatment plants, aquaculture tanks, and natural water bodies.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 35px;\"\u003e\n\u003ch3 style=\"color: #7765e3; font-size: 16px; margin-bottom: 18px; font-weight: bold; text-transform: uppercase;\"\u003eAdvanced Liquid Monitoring\u003c\/h3\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\"\u003e \u003csvg stroke-linejoin=\"round\" stroke-linecap=\"round\" stroke-width=\"2.5\" stroke=\"currentColor\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"20\" width=\"20\"\u003e\u003ccircle r=\"10\" cy=\"12\" cx=\"12\"\u003e\u003c\/circle\u003e\u003cline y2=\"12\" x2=\"22\" y1=\"12\" x1=\"2\"\u003e\u003c\/line\u003e\u003c\/svg\u003e \u003c\/span\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003e90° Light Scattering\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eAdvanced optical fiber structure offers strong resistance to external light interference for precise NTU calculation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\"\u003e \u003csvg stroke-linejoin=\"round\" stroke-linecap=\"round\" stroke-width=\"2.5\" stroke=\"currentColor\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"20\" width=\"20\"\u003e\u003cpath d=\"M12 2v20M2 12h20\"\u003e\u003c\/path\u003e\u003c\/svg\u003e \u003c\/span\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eDual-Parameter Sensing\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eBuilt-in temperature sensor provides secondary environmental data and helps maintain optical stability.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\"\u003e \u003csvg stroke-linejoin=\"round\" stroke-linecap=\"round\" stroke-width=\"2.5\" stroke=\"currentColor\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"20\" width=\"20\"\u003e\u003crect ry=\"2\" rx=\"2\" height=\"10\" width=\"16\" y=\"7\" x=\"2\"\u003e\u003c\/rect\u003e\u003cline y2=\"13\" x2=\"22\" y1=\"11\" x1=\"22\"\u003e\u003c\/line\u003e\u003c\/svg\u003e \u003c\/span\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eRS485 Modbus RTU\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eStandard digital interface ensures easy connection to PLC systems, data loggers, and LoRaWAN DTUs.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 15px; border-radius: 4px; border: 1px solid #f5f5f5; background: #fff;\"\u003e\n\u003cspan style=\"color: #7765e3;\"\u003e \u003csvg stroke-linejoin=\"round\" stroke-linecap=\"round\" stroke-width=\"2.5\" stroke=\"currentColor\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"20\" width=\"20\"\u003e\u003cpath d=\"M11 4H4a2 2 0 0 0-2 2v14a2 2 0 0 0 2 2h14a2 2 0 0 0 2-2v-7\"\u003e\u003c\/path\u003e\u003c\/svg\u003e \u003c\/span\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong style=\"display: block; color: #2a2b2a;\"\u003eEasy Field Service\u003c\/strong\u003e \u003cspan style=\"color: #555;\"\u003eSmooth exterior and robust cable design allow for quick cleaning and periodic zero\/slope calibration in the field.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 35px; background-color: #fafafa; border-left: 4px solid #7765E3; padding: 20px; border-radius: 2px;\"\u003e\n\u003ch3 style=\"color: #7765e3; font-size: 16px; margin-top: 0; margin-bottom: 12px; font-weight: bold; text-transform: uppercase;\"\u003eWater Quality Use Cases\u003c\/h3\u003e\n\u003cdiv style=\"margin: 0; font-size: 15px;\"\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eWastewater Treatment:\u003c\/strong\u003e Monitor effluent clarity and suspended solids levels to ensure environmental compliance.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 10px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eIndustrial Process Water:\u003c\/strong\u003e Track turbidity in cooling towers or filtration systems to maintain equipment health.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 0; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"color: #7765e3; margin-right: 8px; font-weight: bold;\"\u003e•\u003c\/span\u003e \u003cspan\u003e\u003cstrong\u003eEnvironmental Monitoring:\u003c\/strong\u003e Conduct long-term hydrological research in rivers, lakes, and coastal water systems.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch3 style=\"color: #7765e3; font-size: 16px; margin-bottom: 10px; font-weight: bold; text-transform: uppercase;\"\u003eTechnical Integration\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #555;\"\u003eThe S-DTS210-01 operates on a \u003cstrong\u003e12V to 24V DC\u003c\/strong\u003e power supply and provides a robust digital output via \u003cstrong\u003eRS485 Modbus RTU\u003c\/strong\u003e. For wireless deployment, it is perfectly compatible with \u003cstrong\u003eSenseCap\u003c\/strong\u003e series LoRaWAN transmitters and the Milesight development platform. The probe features a 10-meter high-durability cable and is designed for easy mounting via standard submerged brackets. For assistance with water quality network architecture or calibration procedures, contact the \u003cstrong\u003eShopIoT\u003c\/strong\u003e engineering team.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Seeed Studio","offers":[{"title":"Default Title","offer_id":56375246881092,"sku":"101990793","price":259.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0418\/3749\/4423\/files\/SEEED_STUDIO_INDUSTRIAL_TURBIDITY_SENSOR_RS485.jpg?v=1774773158","url":"https:\/\/shopiot.eu\/products\/seeed-studio-s-dts210-01-industrial-turbidity-sensor-rs485","provider":"shopiot","version":"1.0","type":"link"}