Half-price shipping to the EU, UK & Switzerland until 6 Dec · Free on most EU orders over €500 (excl. VAT)

Free help & technical advice Contact us

Indoor Air Quality Monitoring with LoRaWAN: What to Measure and Which Sensor to Buy

shopioT blog banner: Indoor air quality monitoring with LoRaWAN, CO2, PM2.5, TVOC and formaldehyde sensors

Most offices and classrooms never measure the air people breathe for eight hours a day. When they do, the first number that jumps out is usually CO2: a meeting room at 2,000 ppm by mid-afternoon is common, and people feel it as drowsiness and headaches long before anyone blames the ventilation. A LoRaWAN air quality sensor runs on batteries, sticks to a wall in minutes and sends readings every few minutes to a dashboard or building management system. The hard part is choosing which parameters you actually need.

1,000 ppmCO2 level most building guidelines treat as the ventilation warning line
15 µg/m³WHO 24-hour guideline for PM2.5
9 in 1most parameters in one sensor, the Milesight AM319
€71.43entry price for a LoRaWAN CO2 sensor, Dragino AQS01-L
🏫
Who this is forFacility managers, school and clinic operators, and integrators who need indoor air data for comfort, ventilation control or a sustainability report. The guide covers which parameters to measure, what the readings mean, and which sensor fits each room type.

What Each Parameter Tells You

CO2: the ventilation gauge

People breathe out CO2, so its level tracks how well a room is ventilated for the number of people in it. Outdoor air sits around 420 ppm. The European standard EN 16798-1 grades indoor air by how far CO2 rises above outdoor levels, and many building owners use 1,000 ppm as a simple trigger for opening windows or raising fan speed. If you only buy one parameter, buy CO2. It's the best single proxy for stale air, and NDIR CO2 sensors are accurate and stable for years.

PM2.5 and PM10: particles

Fine particles come from traffic, cooking, printers, candles and outdoor pollution drifting in. The WHO 2021 air quality guidelines set 15 µg/m³ as the 24-hour limit for PM2.5 and 45 µg/m³ for PM10. Measure particles near busy roads, in workshops, in kitchens, and anywhere with people who have asthma.

TVOC: chemicals from materials and cleaning

Total volatile organic compounds rise after painting, new furniture or cleaning, and with perfume and air fresheners. A TVOC sensor gives a combined index rather than naming individual chemicals. It's good for spotting a problem and its timing, less good for proving which substance caused it.

Formaldehyde (HCHO): the specialist reading

Formaldehyde comes off pressed-wood furniture, flooring and some insulation, especially in new or renovated buildings. The WHO indoor guideline is 0.1 mg/m³ over 30 minutes. Only the Milesight AM319 HCHO version in our range measures it, using an electrochemical cell with a 0 to 6 mg/m³ range.

Temperature, humidity, light and occupancy

These four are cheap to add and change how you read everything else. A room at 26 °C and 1,200 ppm needs more airflow, not more heating. Humidity below about 30% dries out eyes and throats. Occupancy (PIR) tells you whether a high CO2 reading happened during a full meeting or an empty evening, which matters when you set alarms.

Seven LoRaWAN Air Quality Sensors Compared

Sensor CO2 PM2.5 / PM10 TVOC HCHO Also measures Price
Milesight AM304L No No No No Temp, humidity, light, PIR €84.87
Dragino AQS01-L Yes, NDIR No No No Temp, humidity, pressure €71.43
Milesight AM103 / AM103L Yes, NDIR No No No Temp, humidity; E-ink on AM103 €147.90
Milesight AM307 Yes, NDIR No Yes No Temp, humidity, light, pressure, PIR €204.20
Milesight EM500-CO2 Yes, NDIR No No No Temp, humidity, pressure; rugged housing €210.92
Milesight AM308 / AM308L Yes, NDIR Yes Yes No Temp, humidity, light, PIR €255.46
Milesight AM319 Yes, NDIR Yes Yes HCHO version (O3 version also available) Temp, humidity, light, pressure, PIR €311.76

Prices excl. VAT, starting price per model, checked October 2026. Specifications from Milesight and Dragino product documentation.

⚠️
The AM304L is not a CO2 sensorIt's our most-viewed air sensor, and it's a good one for comfort and occupancy: temperature, humidity, light and PIR on batteries rated up to 7 years. But it has no CO2 cell. If ventilation is the question, step up to the AM103 or the Dragino AQS01-L.

Which Sensor for Which Room

Room Pick Why
Meeting rooms and classrooms AM103 or AQS01-L CO2, temperature and humidity cover the ventilation question at the lowest cost per room
Open-plan office floors AM307 Adds TVOC and occupancy, and the E-ink screen shows staff the air status
Rooms near traffic, workshops, clinics AM308 PM2.5 and PM10 on top of CO2 and TVOC
New builds and fresh renovations AM319 HCHO The only one that reads formaldehyde from new furniture and flooring
Greenhouses, warehouses, plant rooms EM500-CO2 Rugged enclosure and a 19,000 mAh replaceable battery
Comfort and space use only AM304L Cheapest way to log temperature, humidity and occupancy per room

How Many Sensors Does a Building Need?

Plan one CO2 sensor per meeting room or classroom, because each room's ventilation depends on how many people are in it. On open floors, one sensor per 100 to 200 m² of floor area, or one per ventilation zone, is a sensible start. Mount it at breathing height, about 1.2 to 1.5 m, away from windows, doors, radiators and people's desks, where someone exhaling nearby would skew the reading.

A building of 30 rooms needs one or two indoor LoRaWAN gateways, and the sensors report to a network server and then to your platform, which can be a dashboard, the Milesight IoT Cloud or the building management system. Our EPBD smart building reference architecture shows how air sensors fit next to energy meters and room controls.

Air sensorCO2, PM, TVOC
→
LoRaWAN gatewayUG63, UG65, EG71
→
Network serverTTS, ChirpStack, built-in
→
Dashboard or BMSalarms, ventilation

Does EU Law Require Indoor Air Monitoring?

For most existing buildings, not yet in a direct way. The recast Energy Performance of Buildings Directive, Directive (EU) 2024/1275, brings indoor environmental quality into building rules. Article 13 requires new zero-emission non-residential buildings to have devices that measure and control indoor air quality, and existing non-residential buildings to get them at major renovation where technically and economically feasible. Member states may extend this to homes. From 29 May 2026, the building automation systems that larger non-residential buildings must have also need to support monitoring of indoor environmental quality. National rules vary, and several countries already set CO2 limits for schools. Check your national transposition, and our post on the EPBD BACS mandate for the building automation side.

✅
Readings that change behaviourSensors with a screen, like the AM103, AM307 and AM308, show a traffic-light status in the room. In schools and offices, a visible red face on the wall gets windows opened faster than any email from facilities.

Frequently Asked Questions

What is a good CO2 level indoors?

Below 800 ppm is good, and most building guidelines treat 1,000 ppm as the point to increase ventilation. Outdoor air is around 420 ppm. EN 16798-1 grades indoor air by how far CO2 rises above the outdoor level, so a well-ventilated office typically stays within a few hundred ppm of outside.

Which LoRaWAN sensor measures CO2, PM2.5 and TVOC together?

The Milesight AM308 measures CO2, PM2.5, PM10 and TVOC along with temperature, humidity, light and occupancy. The AM319 adds pressure and either formaldehyde or ozone. Both send data over LoRaWAN.

Does the Milesight AM304L measure CO2?

No. The AM304L measures temperature, humidity, light and PIR occupancy. For CO2, choose the AM103, AM307, AM308, AM319 or the Dragino AQS01-L.

Where should an indoor air quality sensor be mounted?

On an inside wall at breathing height, about 1.2 to 1.5 m, away from windows, doors, air vents, radiators and direct sunlight. Don't place it right next to a desk, where one person's breath can push the CO2 reading up.

Can air quality sensors control ventilation automatically?

Yes. The readings go to a network server and then to a building management system, which can raise fan speed or open dampers when CO2 passes a threshold. Gateways such as the Milesight UG56 and EG71 can also pass data to BACnet or Modbus systems.

Start With CO2, Add the Rest Where It Earns Its Place

A CO2 sensor in every occupied room answers the ventilation question for under €150 a room. Add particle sensing where there's traffic, cooking or vulnerable occupants, and formaldehyde where the building or furniture is new. That mix gives you data people will act on without paying for nine sensors in a storage cupboard.

Planning Air Quality Monitoring for a Building?

shopioT is the webstore of CyRIC IoT, an official Milesight and Dragino distributor. Tell us the room count and use, and we'll suggest a sensor mix and the gateway to go with it.

Sources

Leave a comment

Please note: comments must be approved before they are published.